Right-click the Auxiliary Settings node to add a Disable Allowed Study Types node () do disable some allowed study types from some space dimensions, for example.
To add study types toe disable, click the Add buttonand then select from the Disabled study types list in the Add dialog box that opens.
Select the Restrict to space dimensions check box and use the buttons under the table to add or edit the list.
• For User input in property (the default) enter a Property and a User input. Choose the User input condition: User input is active (the default) or User input has any of certain values. as needed enter values in the table.
• Select the Condition is not fulfilled for undefined references check box to if you want the condition to be treated as not fulfilled instead of throwing an error if the property is undefined.